Below are the specifications by type.
TITAN-PORT APH:
Implantable port catheter system for extracorporeal apheresis.
Indications:
- Long-term high-volume venous access to the central vascular system.
- Therapeutic apheresis
Product specifications:
- With single-lumen catheter
- Self-healing silicone membrane
- Easy and secure screw connection between port chamber and catheter
- Pressure stability
- Sufficient flow and persistence only with accompanying special cannulae
- Latex-free
TITAN-PORT AS/PT:
Implantable port catheter system for ascites puncture and peritoneal therapy.
Indications:
- Ascites puncture
- Peritoneal therapy
Product Specifications:
- Catheter with perforations.
- Self-healing silicone membrane
- Simple and secure screw connection between port chamber and catheter
- Pressure stability
- Sufficient flow and persistence only with the corresponding special cannulae
- Latex-free
TITAN-PORT D:
Implantable port catheter system for venous - venous hemodialysis - single lumen - double lumen.
Indications:
- Venous access in renal failure
- Venous access with large lumen
Product specifications:
- With single or double lumen catheter
- Self-healing silicone membrane
- Simple and secure screw connection between port chamber and catheter
- Pressure stability
- Sufficient flow and persistence only with the corresponding special cannulae
- Latex-free
TITAN-PORT F:
(Fetal port) Prenatal port system.
Indications:
- Intrauterine growth restriction caused by placental insufficiency (IUGR) AFR-PORT (amniotic fluid replacement PORT-SYSTEM).
- Early membranous birth with anhydramnion (PPROM)
Product specifications:
Fetal:
Contraindication: posteriorly located placenta.
Purpose: Improve fetal growth, prolong pregnancy.
Use: long-term administration of umbilical vein nutrients such as amino acids and glucose through the portal system.
Period: during the 24-32nd week of pregnancy with IUGR (Intrauterine Growth Restriction) estimated fetal weight <10th percentile, pathological Doppler ultrasound monitoring findings.
Placement: port implantation can only be performed in pregnant women with anterior or anterior-lateral placenta.
Duration: daily, volume of intra-umbilical infusion limited to 10% of estimated feto-placental blood volume per day.
AFR:
Contraindication: cervical insufficiency, infection, contractions
Purpose: Prolongation of pregnancy, reduction of perinatal morbidity and mortality
Use: long-term amnioinfusion through a subcutaneously implanted port system
Period: between 22-30th week of pregnancy in PPROM until delivery to replace fluid loss
Placement: ultrasound-guided placement of catheter in the amniotic cavity
Duration: contiunuous infusion of 50-120 ml/h Amnion Flush Solution via port system
TITAN-PORT G:
Implantable port catheter system.
Indications:
- Long-term venous access.
- Systemic chemotherapy
- Drug delivery
- Regional chemotherapy
- Pain therapy
- Blood sampling, poor vascular status
- Prolonged infusion therapy and parenteral nutrition
Product specifications:
- Specialty: no more requirement for special port needles!
- Self-healing silicone membrane
- Simple and secure screw connection between port chamber and catheter
- Pressure stability
- Catheter with additional side holes and length markings
- Optimized design
- Simple handling
- Long-term high quality
- Latex-free
One port for all needles:
- Technical failures excluded > increased safety
- Cost savings by using "normal" needles for puncture
- No punching defects in the membrane of the port
Set consists of:
1 Titan-Port, 1 single-lumen catheter, 1 special puncture needle, 1 introducer set, 1 tunnelizer, 1 port needle, 1 vein lifter and 1 coil needle.
TITAN-PORT UA:
Implantable port catheter systems e.g. upper arm.
Indications:
- Long-term venous access.
- Systemic chemotherapy
- Drug delivery
- Regional chemotherapy
- Pain therapy
- Blood sampling, poor vascular situation
- Prolonged infusion therapy and parenteral nutrition
Product specifications:
- Catheter with extra hole on the side
- Self-sealing silicone membrane
- Simple and secure screw connection between port chamber and catheter
- Pressure stability
- Sufficient flow and persistence only with the accompanying special cannula
Would you like to receive more information about this product, or request a quote? Klik hier!
Product information
| Color | Multiple |
| Size | Multiple |
| Product code | See product table |
| Unit of Measure | BOX/10 SETS |